WATER ACTIVITY SERIES BY ROTRONIC
Water activity (aw) is one of the most critical factors in determining quality and safety of the goods you consume every day. Water activity affects the shelf life, safety, texture, flavor, and smell of foods.








Most bacteria, for example, do not grow at water activities below 0.91, and most molds cease to grow at water activities below 0.80. By measuring water activity, it is possible to predict which microorganisms will and will not be potential sources of spoilage. Water activity--not water content--determines the lower limit of available water for microbial growth. In addition to influencing microbial spoilage, water activity can play a significant role in determining the activity of enzymes and vitamins in foods and can have a major impact their color, taste, and aroma. It can also significantly impact the potency and consistency of pharmaceuticals. 
HP 23AW is the latest development of handheld instruments for relative humidity, temperature and all psychometric values such as dew point and absolute humidity.  It features twin probe inputs, can data log up to 20000 values and is fully configurable using a PC.



Two probe inputs are especially useful when performing on-site calibration checks on fixed transmitters. The dual inputs can also accept analogue signals, so the HP23 can be used with a pressure or airflow sensor.  A truly universal handheld instrument. 
 It is also important to the stability of pharmaceuticals and cosmetics. While temperature, pH and several other factors can influence if and how fast organisms will grow in a product, water activity may be the most important factor in controlling spoilage.
HYGROLAB C1 BENCH TOP METER

AC adapter (115 VAC / 9 VDC)

HC2-AW probe for the measurement of product samples

WP40 sample holder with depth reduction insert

PS14: pack of 100 disposable sample cups (14mm deep)

PS40: pack of 100 disposable sample cups (40mm deep)

1 box each: EA00 (0 %RH), EA10 (10 %RH), EA35 (35 %RH),
 EA80 (80%RH) and EA95 (95%RH) humidity calibration standards

HW4 software CDROM

1.8m USB cable for connection of a PC

WHITESTONE VA
TEL (804) 318-3686 FAX (703) 991-7133
INFORMATION@QCLABEQUIPMENT.COM 
WWW.QCLABEQUIPMENT.COM
Copyright 2012: QAQC Lab | Particle Measurement System | All rights reserved.
804-318-3686 | sales@qclabequipment.com
WHICH METHOD WILL SUIT YOUR APPLICATION THE BEST?
Chilled Mirror Dewpoint vs Capacitance
The question as to whether the chilled mirror dewpoint method of determining water activity, or the capacitance based method is better for an application, has primarily to do with accuracy and convenience. The chilled mirror dewpoint method is a primary method, and has an accuracy of +/- .003 aW, compared to +/-.008 aW for the Rotronic capacitance based sensors.
 

Capacitance based water activity meters use an indirect method of determining water activity, and are slightly less accurate, although well within the accuracy parameters for quality control usage, but provide more features and convenience 

Probe type sensors are available, as well as hand held instruments and sophisticated software, with report generation capabilities.
EQUIPMENT FOR QUALITY CONTROL AND R&D 
www.qclabequipment.com
Telephone      (804) 318-3686
Toll Free US    (866) 244 1578
Fax                   (703) 991-7133
Hours      8 AM - 6 PM EST
INTERNATIONAL & DOMESTIC SALES
CUSTOMER SERVICE * SALES * TECHNICAL SUPPORT


DELIVERIES WORLDWIDE

PERFORMANCE GUARANTEE
MANUFACTURING
DISTRIBUTION
TECHNICAL SERVICES ​FOR
ANALYTICAL INSTRUMENTATION

TELEPHONE (804) 318-3686
TOLL FREE   (866) 244-1578
SAMPLER CATALOGUE